©Endress+Hauser
Specs at a glance
Input
Foundation Fieldbus protocol PROFIBUS PA protocol
Display
High contrast backlit LCD with bargraph TAG/unit
Field of application
The 8 channel indicator shows measured and calculated values, and status information of the fieldbus users in a FOUNDATION Fieldbus™ or PROFIBUS® PA network. In the listener mode the device listens to the set fieldbus addresses and indicates their values. In addition, for FOUNDATION Fieldbus™ values available on the bus can be indicated via function block interconnection. A plain text field allows the display of the engineering unit or of the TAG. A bargraph is available for trend visualization.
Fieldbus indicator with 8 input channels and FOUNDATION Fieldbus™ or PROFIBUS® PA protocol for displaying process values and calculated values.
Benefits
Simple and standardized communication via fieldbus protocol
Listener mode for up to 8 analog channels or digital status
Brilliant, back lit LC display with bargraph, diagnostic symbols and clear text field
No external power supply required
International approvals
Loading alternative products
Predecessor
PROFIBUS-PA indicator RID261
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Measuring principle
8 channel field indicator for fieldbuses
Function
Display values Advanced diagnostic
Display
High contrast backlit LCD with bargraph TAG/unit
Input
Foundation Fieldbus protocol PROFIBUS PA protocol
Software functions
Listener Mode On Foundation Fieldbus also function block connection: Display transducer block Advanced diagnostic block 2 x input selector Arithmetic block Integrator block PID block
Certificates
ATEX Ex ia CSA General Purpose CSA IS, NI FM IS, NI IECEx Ex ia IND Ex PESO Ex
Most downloaded
RID16
Operating Instructions
English version - 09/2016
Operating Instructions for RID16 field indicator with PROFIBUS® PA
protocol
EN
DE ES FR IT JA PT RU ZH
13/09/2016
22/10/2013
Language:
English
Version:
13/09/2016
File size:
2.2 MB
File name:
BA01268KEN_0216.pdf
RID16
Operating Instructions
English version - 09/2016
Operating Instructions for RID16 field indicator with FOUNDATION
Fieldbus™ protocol
EN
DE ES FR IT JA PT RU
13/09/2016
22/10/2013
24/02/2010
01/12/2009
Language:
English
Version:
13/09/2016
File size:
2.3 MB
File name:
BA00284REN_1416.pdf
49 documents
8-channel field indicator with FOUNDATION Fieldbus™ or PROFIBUS® PA protocol
EN
German Spanish French Italian Japanese Portuguese Russian Chinese
27/02/2023
13/09/2016
29/09/2015
24/10/2013
26/11/2009
Language:
English
Version:
27/02/2023
File size:
646.4 KB
File name:
TI00146REN_1623-00.pdf
RID16
Operating Instructions
Operating Instructions for RID16 field indicator with PROFIBUS® PA protocol
EN
German Spanish French Italian Japanese Portuguese Russian Chinese
13/09/2016
22/10/2013
Language:
English
Version:
13/09/2016
File size:
2.2 MB
File name:
BA01268KEN_0216.pdf
RID16
Operating Instructions
Operating Instructions for RID16 field indicator with FOUNDATION Fieldbus™ protocol
EN
German Spanish French Italian Japanese Portuguese Russian
13/09/2016
22/10/2013
24/02/2010
01/12/2009
Language:
English
Version:
13/09/2016
File size:
2.3 MB
File name:
BA00284REN_1416.pdf
8-channel field indicator with PROFIBUS® PA protocol
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Indonesian Italian Japanese Korean Lithuanian Latvian Dutch Norwegian Polish Portuguese Romanian Russian Slovak Slovenian Swedish Thai Turkish Chinese
17/05/2023
08/09/2016
16/10/2014
14/10/2013
Language:
English
Version:
17/05/2023
File size:
1.5 MB
File name:
KA01157KEN_0223-00.pdf
RID16
Brief Operating Instructions
Brief operating instructions RID16 8-channel field indicator with FOUNDATION Fieldbus™ protocol
EN
German
08/09/2016
16/10/2014
01/12/2009
Language:
English
Version:
08/09/2016
File size:
1.3 MB
File name:
KA00283RA2_1416.pdf
Einbauanleitung Austausch Gehäuse RIx16
Language:
English
Version:
03/03/2025
File size:
391.6 KB
File name:
71098930.pdf
Einbauanleitung Austausch LC-Display RIx16
Language:
English
Version:
03/03/2025
File size:
244.8 KB
File name:
71098927.pdf
EA Elektroik RIA16; RID16
Einbauanleitung Elektroik RIA16; RID16
Language:
English
Version:
12/01/2026
File size:
228.9 KB
File name:
71098931.pdf
FOUNDATION Fieldbus™/PROFIBUS PA® CSA: Control Drawing IS, NI, DIP 120600112
Language:
English
Version:
30/01/2026
File size:
99 KB
File name:
120600112.pdf
FOUNDATION Fieldbus™/PROFIBUS PA® FM: Control Drawing IS, NI, DIP 120600111
Language:
English
Version:
06/07/2009
File size:
1.4 MB
File name:
120600111.pdf
Search spare parts by number in drawing
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Drawing number
Order code
9
RIA16X-
Drawing number
Order code
5
RID16X-
Drawing number
Order code
2,1,4
RID16X-
Drawing number
Order code
7,8
RIA16X-
Plug for Thermometer + Transmitter
Drawing number
Order code
6
XPT0002-
Accessories System Products
Drawing number
Order code
6
RK01-
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all