Specs at a glance
Max. measurement error
2% - 10% (per measurement range)
Medium temperature range
-20...+85°C (-4...+185°F) CIP-able to 130°C / 266°F
Field of application
The switch is designed for the safe measurement, display and monitoring of relative mass flow rates of liquid media with practically no pressure loss. It can be selected between one or two switch outputs as well as one switch output and one standardized analog output for flow rates or temperature values. Typical applications are: Monitoring cooling water circulation processes or lubrication systems of pumps and heat exchangers or leak monitoring in process lines.
Flow switch for monitoring and displaying relative mass flow rates of liquid media in the range from 0.03 to 3 m/s (0.1 to 9.84 ft/s). Flowphant T DTT31 − with thread connections or coupling.
Application examples:
Monitoring cooling water circulation systems of pumps, turbines, compressors and heat exchangers
Leak monitoring in process lines
Monitoring pump functionality
Monitoring lubrication systems
Filter monitoring in the beverage industry
Benefits
Practically no pressure loss
Configuration software FieldCare for quick configuration and reliable storage of device settings
Optional: second switch output or 4 to 20 mA analog output for temperature monitoring or for outputting the flow as a percentage
Function check and process information onsite thanks to digital display at device
Top housing section which can be rotated 310° and rotatable display make it possible to read the measured values in all orientations
Marine approval
Fundamental selection
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
©Endress+Hauser
Simple products
Easy to select, install and operate
Technical excellence
Simplicity
Standard products
Reliable, robust and low-maintenance
Technical excellence
Simplicity
High-end products
Highly functional and convenient
Technical excellence
Simplicity
Specialized products
Designed for demanding applications
Technical excellence
Simplicity
FLEX selections
Technical excellence
Simplicity
Fundamental selection
Meet your basic measurement needs
Technical excellence
Simplicity
Lean selection
Handle your core processes easily
Technical excellence
Simplicity
Extended selection
Optimize your processes with innovative technologies
Technical excellence
Simplicity
Xpert selection
Master your most challenging applications
Technical excellence
Simplicity
Loading alternative products
Success stories
Reliable flow measurement despite difficult conditions
Schluchseewerk AG wanted to record and optimize the efficiency of its turbines at the pumped storage plant in Wehr. Endress+Hauser offers the optimum solution with its ultrasonic clamp-on flowmeter.
Read the full story
Simplified quality control in distilleries
Waldbrand Destillerie uses Teqwave to continuously measure the alcohol concentration. The device can compensate for cross-influences and can be adapted to beverage-specific properties
Read the full story
Product headline
Flow switch for liquid applications, intelligent / programmable; insertion style
Max. measurement error
2% - 10% (per measurement range)
Medium temperature range
-20...+85°C (-4...+185°F) CIP-able to 130°C / 266°F
Outputs
1 x PNP switchable output + 1 x 4...20 mA analog output
Most downloaded
Flowphant T DTT31, DTT35
English version - 11/2020
Flow switch for the safe and reliable monitoringof mass flow rates and
temperature in industrial processes
EN
DE ES FR IT JA PL PT RU ZH
30/11/2020
15/02/2018
09/04/2014
16/08/2011
10/06/2009
Language:
English
Version:
30/11/2020
File size:
1.1 MB
File name:
TI00125REN_0420.pdf
Flowphant T DTT31, DTT35
English version - 11/2020
Flow switch
EN
BG CS DA DE EL ES ET FI FR HR HU ID IT JA KO LT LV NL NO PL PT RO RU SK SL SV TH TR ZH
30/11/2020
15/02/2018
02/04/2014
16/01/2014
04/07/2013
Language:
English
Version:
30/11/2020
File size:
1.1 MB
File name:
BA00235REN_1820.pdf
22 documents
TI Weld-in adapter, process adapter and flanges
Level, pressure and temperature measurement
EN
German Spanish French Italian Japanese Polish Portuguese Russian Chinese
15/09/2023
28/10/2021
30/07/2021
19/06/2020
08/11/2019
Language:
English
Version:
15/09/2023
File size:
2.9 MB
File name:
TI00426FEN_2423.pdf
Flow switch for the safe and reliable monitoringof mass flow rates and temperature in industrial processes
EN
German Spanish French Italian Japanese Polish Portuguese Russian Chinese
30/11/2020
15/02/2018
09/04/2014
16/08/2011
10/06/2009
Language:
English
Version:
30/11/2020
File size:
1.1 MB
File name:
TI00125REN_0420.pdf
EN
Bulgarian Czech Danish German Greek Spanish Estonian Finnish French Croatian Hungarian Indonesian Italian Japanese Korean Lithuanian Latvian Dutch Norwegian Polish Portuguese Romanian Russian Slovak Slovenian Swedish Thai Turkish Chinese
30/11/2020
15/02/2018
02/04/2014
16/01/2014
04/07/2013
Language:
English
Version:
30/11/2020
File size:
1.1 MB
File name:
BA00235REN_1820.pdf
Operating Instructions
Flow switch
Flowphant T DTT31, DTT35
Flow switch for safe measurement and monitoring of mass flow and temperature in industrial processes
EN
Czech German French Italian
08/02/2006
Language:
English
Version:
08/02/2006
File size:
1023.5 KB
File name:
Ba218ren.pdf
Operating Manual ReadWin® Quick Setup Temperature PC Software
Language:
English
Version:
02/02/2005
File size:
883.5 KB
File name:
Ba213ra2.pdf
Flow, density, concentration, viscosity
Language:
English
Version:
04/11/2022
File size:
357.4 KB
File name:
SD02752DEN_0222-00.pdf
Technical documentation in other languages
Language:
English
Version:
14/07/2021
File size:
478.5 KB
File name:
SD02429R09EN_0121.pdf
Catálogo soluciones esenciales
Alta calidad a precios competitivos
Language:
Spanish
Version:
16/01/2017
File size:
8.9 MB
File name:
CP01266Z.pdf
Product root: DTT31- Declaration number: HE_00470_01.17 Manufacturer specification: RoHS
Language:
English
Version:
13/03/2017
File size:
161.4 KB
File name:
HE_00470_01.17 China RoHS DTT31.pdf
Product family: Accessories: Bar stock thermowell, Accessories: Pipe thermowell, Accessories: Inserts, Magphant, Process RTD general
purpose, Process RTD hygienic, RTD thermometer
Product root: DTT31-, DTT35-, TK40-, TM101-, TM111-, TM121-, TM131-, TM311-, TM371-, TM372-, TM401-, TM402-, TM411-, TM412-, TMR35-, TS111-, TS212-, TT131-, TT151-, TT411-, TT412- Declaration number: HE_01494_01.21 Manufacturer specification: Food hygiene Additional information: BSE, TSE
Language:
English
Version:
27/07/2023
File size:
266 KB
File name:
HE_00886_07_17.pdf
60 spare parts & accessories
60 spare parts & accessories
60 spare parts & accessories
Commubox FXA291 (Hardware)
Gasket rubber cap CDI-connector
Collar welded socket d6 PEEK + screw
Collar welded socket d6 PEEK w/o screw
M12 elbow plug ready for cable, IP67,PG7
We value your privacy
We use cookies to enhance your browsing experience, collect statistics to optimize site functionality, and deliver tailored advertisements or content.
By selecting "Accept all", you consent to our use of cookies.
For further details please review our cookie policy .
Customize
Accept only essential
Accept all
Welcome to Endress+Hauser!
Please select your market / region
Market / Region
Antigua and Barbuda Aruba Bahamas Barbados Belize Bolivia Bonaire Costa Rica Cuba Curaçao Dominica Dominican Republic Ecuador El Salvador Grenada Guatemala Guyana Haiti Honduras Jamaica Nicaragua Panama Paraguay Peru Saint Kitts and Nevis Saint Lucia Saint Vincent and the Grenadines Trinidad and Tobago Uruguay Venezuela
Language
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish
English Spanish