Ultrasonic measurement
Time-of-Flight
Prosonic FDU90
Ultrasonic sensor for level and flow measurement for connection to FMU9x (measuring range up to 3m)
The FDU90 ultrasonic sensor for continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. But also for flow measurement in open channels and measuring weirs. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of sensors. Suited for explosion hazardous areas. Maximum measuring range in liquids 3m (9.8ft), solids 1.2m (3.9ft).
-
Benefits
Integrated temperature sensor for Time-of-Flight correction. Accurate measurements are possible, even if temperature changes are present
Hermetically welded PVDF sensor for highest chemical resistance
Suited for rough ambient conditions thanks to separate...
-
Field of application
Sensor for continuous, non-contact level measurement of fluids and bulk materials in silos, on belts, stockpiles and in crushers. Also flow measurement in open channels and at weirs. Typically used in measurements in low structural heights.
Process...
Documents / Manuals / Software
-
Flange
DIN - EN -ASME - JIS
Flange
DIN - EN -ASME - JISTechnical Information (TI) -
Prosonic S
FDU90/91/91F/92/93/95
Technical Information/Operating Instructions
Ultrasonic sensors for non-contact continuous level and flow
measurementTechnical Information (TI) -
Safety Instructions
Prosonic S FDU90/91, FDU91F, FDU92/93/95
Ex ma IIC T5 Gb (FDU90)
Ex ma IIC T6 Gb (FDU91/91F/92/93/95)
Ex ta/tb IIIC Txx°C Da/Db IP65
Ex tb IIIC Txx°C Db IP65
TÜV 13.0893 X (INMETRO)Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU90, FDU91, FDU91F, FDU92
Ex ma IIC T5 Gb (FDU90)
Ex ma IIC T6 Gb (FDU91, FDU91F, FDU92)
TÜV 13.0893 X (INMETRO)Ex Safety Instructions (XA) -
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95, FDU96
IECEx BVS 08.0012
Ex ma IIC Tx Gb
Ex ta/tb IIIC Txx°C Da/Db IP68
Ex tb IIIC Txx°C Db IP68Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95
Ex ma IIC T5 Gb
Ex ma IIC T6 Gb
Ex tD A20/21 IP65 T
GYJ16.1246 (NEPSI)Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU90, FDU91, FDU91F, FDU92
II 2 G Ex ma IIC T5 Gb (FDU90)
II 2 G Ex ma IIC T6 Gb (FDU91, FDU91F, FDU92)
BVS 05 ATEX E 009Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU90, FDU91, FDU91F, FDU92
Ex ma IIC T5 Gb
Ex ma IIC T6 Gb
GYJ16.1246 (NEPSI)Ex Safety Instructions (XA) -
Prosonic S FDU90, FDU91, FDU91F, FDU92
EAC:
1Ex ma IIC T6, T5 Gb
Safety Instructions
Ultrasonic Level Measurement
Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95
II 2 G Ex ma IIC T5 Gb (FDU90)
II 2 G Ex ma IIC T6 Gb (FDU91/91F/92/93/95)
II 1/2 D Ex ta/tb IIIC Txx°C Da/Db IP68
II 2 D Ex tb IIIC Txx°C Db IP68
BVS 05 ATEX E 009Ex Safety Instructions (XA) -
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95
EAC:
Ex ta/tb IIIC T°C Da/Db
Ex tb IIIC T°C Db
1Ex ma IIC T6, T5 Gb
Safety Instructions
Ultrasonic Level Measurement
Ex Safety Instructions (XA) -
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95
EAC:
2Ex nA IIC T6...T3 Gc
Ex tc IIIC T55...95°C Dc
Safety Instructions
Ultrasonic Level Measurement
Ex Safety Instructions (XA) -
Safety Instructions
Prosonic S FDU90, FDU91, FDU91F, FDU92, FDU93, FDU95
II 3 G Ex nA IIC T5 Gc (FDU90)
II 3 G Ex nA IIC T6 Gc (FDU91-93/95, FDU91F)
II 3 D Ex tc IIIC Txx°C Dc
EG 05 024Ex Safety Instructions (XA) -
Prosonic S FDU90, FDU91, FDU91F, FDU92
IECEx BVS 08.0012
Ex ma IIC T5 Gb (FDU90)
Ex ma IIC T6 Gb (FDU91/91F/92)Ex Safety Instructions (XA) -
Flooding protection tube for the FDU90 ultrasonic sensor
Flooding protection tube for the FDU90 ultrasonic sensor
Special Documentation (SD) -
Fachbericht:40 Jahre Ultraschall-Füllstandmesstechnik
Fachbericht:Dieses Jahr feiert Endress+Hauser das 40jährige Bestehen der
Ultraschall-Füllstandmesstechnik, mit der bis heute mehr als 500.000
Anwendungen gelöst wurden. Dass diese Technik auch heute noch viele
Vorteile bietet, zeigt die aktuelle Entwicklung von Neuprodukten.Publications (PU)11/09German -
Mesure de niveau
Aperçu des produits pour des applications dans des liquides et des
solides en vracFields of Activities (FA)03/19fr -
Füllstandmesstechnik
Produktübersicht für Anwendungen in Flüssigkeiten und Schüttgütern
Fields of Activities (FA)03/17German -
Catálogo Medición y Detección de nivel
Gama de productos para aplicaciones con líquidos y sólidos
Fields of Activities (FA)03/17Spanish -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Level measurement
Product overview for applications in liquids and bulk solids
Fields of Activities (FA)03/17English -
Level measurement in polymer station with ultrasonic level sensor
For the different treatment processes, wastewater plants produce huge
amounts of sewage sludge annually. Since this must be disposed of
through landfill or incineration, it is essential to try to render
residual
sludge as dry as possible.Case Studies (CS)06/11English -
Prosonic S
Füllstandmessung in der Polymerstationmit Ultraschall-Füllstandsensor
Case Studies (CS)02/11German -
Inexpensive volume measurement at storm water basins with ultrasonic
level sensor
In wastewater treatment plants and sewer systems, numerous
measurements are performed in hostile environments. One example is the
level and volume measurement in storm water basins.Case Studies (CS)01/11English -
Prosonic S FDU90 im Klärwerk
Im Klärwerk des Abwasserverband Bergstraße, Stadt Weinheim, wird
jetzt die Füllstand- und Abschlagmengenmessung im
Regenüberlaufbecken mittels Prosonic S FDU90 durchgeführt.Case Studies (CS)01/11German -
Prosonic S, FDU 9x
(FDU90, FDU91 FDU92 FDU93 FDU95 FDU96)
Ultraschall-Füllstandmessstelle mit Sensor und abgesetztem Messumformer.
Füllstand-Messwertaufnehmer zur kontinuierlichen Füllstandmessung in
offenen
Behältern.Tender Text11/16German -
Prosonic S, FDU90
Ultrasonic sensor for non-contact level measurement
Tender Text03/10English -
Prosonic S, FDU 90
Ultraschallsensor zur berührungslosen Füllstandmessung
Tender Text03/10German -
Radar or ultrasonic measurement
Animation FR 1280x720 mp4
Animation07/16fr -
Radar or ultrasonic measurement
Animation DE 960x540 mp4
Animation07/16German -
Radar or ultrasonic measurement
Animation flv EN
Animation06/15English -
Radar or ultrasonic measurement
Animation mp4 EN
Animation06/15English -
Prosonic S
Product Code: FDU90-
Declaration Number: HE_00614_01.17
Manufacturer Specification: RoHSManufacturer DeclarationChinese -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-
EU DeclarationGerman , English , fr -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-
Declaration Number: EG 05 024EU DeclarationGerman , English , fr -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-
Declaration Number: EC_00196_03.16EU DeclarationGerman , English , fr -
Prosonic M, Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TС RU D-DE.MU62.B.02534MiscellaneousRussian -
Levelflex, Micropilot, Soliphant T, Soliphant M, Solicap S, Solicap M, Prosonic S, Prosonic M, Nivector, Minicap
Product Code: FMP57-, FMP56-, FMR57-, FMR56-, FMR67-, FTM52-, FTM51-, FTM50-, FTM21-, FTM20-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC968-, FTC262-, FTC260-, FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90-
Region/Country: Russia (Declaration of Conformity), Russia (TR CU)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05554MiscellaneousRussian -
Prosonic M, Prosonic S
Product Code: FDU90-, FDU91-, FDU92-, FDU93-, FDU95-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FMU90-, FMU95-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC № RU D-DE.AL32.B.07214MiscellaneousRussian -
Levelflex, Micropilot, Soliphant T, Soliphant M, Solicap S, Solicap M, Prosonic S, Prosonic M, Nivector, Minicap
Product Code: FMP57-, FMP56-, FMR57-, FMR56-, FMR67-, FTM52-, FTM51-, FTM50-, FTM21-, FTM20-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC968-, FTC262-, FTC260-, FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90-
Region/Country: Russia (Declaration of Conformity), Russia (TR CU)
Approval Agency: EAC
Approval Number: RU D-DE.MO10.B.05551MiscellaneousRussian -
SYSTEM, Prosonic S, Prosonic M, Micropilot S, Micropilot, Liquipoint T, Liquipoint, Liquiphant S, Liquiphant M, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Levelflex, Einstabsonde, Dreistabsonde, Doppelstabsonde
Product Code: FMR60-, FMR62-, FMU40-, FMU41-, FMU42-, FMU43-, FMU44-, FTI51-, FTI52-, FTL31-, FTL33-, FTL50-, FTL50H-, FTL51-, FTL51C-, FTL51H-, FTL70-, FTL71-, FTL80-, FTL81-, FTL85-, FTW23-, FTW31-, FTW32-, FTW33-, NMR81-, NMR84-, FMR540-, 11362Z-, 11363Z-, 11371-, 11375Z-, 11961Z-, FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FMI21-, FMI51-, FMI52-, FMP50-, FMP51-, FMP52-, FMP53-, FMP54-, FMP55-, FMR10-, FMR20-, FMR50-, FMR51-, FMR52-, FMR53-, FMR532-, FMR54-
Region/Country: Russia (TR CU), Russia (Declaration of Conformity)
Approval Agency: EAC
Approval Number: EAEC_N_C-DE.MU62.B.0006019MiscellaneousRussian -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91-, FDU90-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Approval Number: TC BY_112 11.01. TP020 003 127MiscellaneousRussian -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex m, Ex tbExplosion ProtectionPortuguese -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-
Region/Country: International (IECEx)
Approval Agency: DEKRA
Protection: Ex tb IIIC Txxx°C Db, Ex ta/tb IIIC Txxx°C Da/Db, Ex ma IIC T5 Gb, Ex ma IIC T6 GbExplosion ProtectionEnglish -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I/2/A,B,C,D/T5, I/2/A,B,C,D/T3C, I,II,III/1,2/A,B,C,D,E,F,G/T5, I,II,III/1,2/A,B,C,D,E,F,G/T6, II,III/1/E,F,G/T5, II,III/1/E,F,G/T3CExplosion ProtectionEnglish -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-
Approval Agency: FM
Category: I,II,III 1,2 ABCDEFG
Protection: DIP, SExplosion ProtectionEnglish -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-
Region/Country: Europe (ATEX)
Approval Agency: EXAM (DMT, BVS)
Category: II 2 D, II 2 G, II 1/2 D
Protection: Ex tb IIIC Txxx°C Db, Ex ta/tb IIIC Txxx°C Da/Db, Ex ma IIC T5 Gb, Ex ma IIC T6 GbExplosion ProtectionGerman , English -
Prosonic S
Product Code: FDU96-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90-
Region/Country: Europe (ATEX)
Approval Agency: EXAM (DMT, BVS)
Category: II 2 G, II 1/2 D, II 2 D
Protection: Ex ta/tb IIIC Txx°C Da/Db IP65, Ex tb IIIC Txx°C Db IP65, Ex ma IIC T6/T5 GbExplosion ProtectionGerman , English -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90-
Region/Country: Russia (TR CU)
Approval Agency: EAC
Protection: Ex d [ia], Ex ia, Ex m, Ex nA, Ex t, Ex ta/tc, Ex ta/tbExplosion ProtectionRussian -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-
Region/Country: Brazil
Approval Agency: TÜV
Protection: Ex m, Ex tbExplosion ProtectionPortuguese -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-
Region/Country: Canada, USA
Approval Agency: CSA
Category: I,II,III 1 ABCDEFG
Protection: 6P, ExmExplosion ProtectionEnglish -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-
Region/Country: China
Approval Agency: NEPSI
Category: zone 0, zone 20,21
Protection: Ex tD A20/A21 IP6X IIIC Txxx°C Da/Db, Ex ma II T5, Ex ma II T6Explosion ProtectionChinese -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-
Approval Agency: FM
Category: I/1,2/A,B,C,D/T5, I/1,2/A,B,C,D/T6, II,III/1,2/E,F,G/T4AExplosion ProtectionEnglish -
Micropilot S, Liquiphant S, Levelflex, Micropilot, Liquiphant M, Minicap, Nivector, Prosonic M, Prosonic S, Prosonic T, Pumpenschutz, Solicap M, Solicap S, Soliphant M, Soliphant T, SYSTEM, Liquipoint T, Liquipoint, Liquiphant FailSafe, Liquiphant, Liquicap T, Liquicap M, Einstabsonde, Dreistabsonde, Doppelstabsonde
Product Code: FTL51-, FMP54-, FMP52-, FMR52-, FMR54-, FMP57-, FMP55-, FMP51-, FMR51-, FMR57-, FMP53-, FMR56-, FMP56-, FMR53-, FMR50-, FMP50-, FMU41-, FMU42-, FTL51H-, FTL50H-, FMU43-, FMU44-, FTL51C-, FTL70-, FMU40-, FMI52-, FTL50-, FTL71-, FTM51-, FTI52-, FMR532-, FTL81-, FMI51-, FMR533-, FTI51-, FTL85-, FTM52-, FTL33-, FTL31-, FTI77-, FTI56-, FTI55-, FTC968Z-, FTC262-, FTC260-, FTL80-, FTM20-, FTM21-, FTM50-, FTW23-, FTW31-, FTW32-, FTW33-, FTW360-, NMR84-, NMR81-, 11263-, 11362Z-, 11363Z-, 11375Z-, 11961Z-, FDU90-, FDU91-, FDU91F-, FDU92-, FDU95-, FDU96-, FDU93-, FMI21-, FMU30-, FMR540-, FMR530-, FMR10-, FMR20-
Approval Agency: TÜVPressure EquipmentGerman , English -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91F-, FDU91-, FDU90-
Region/Country: Kazakhstan
Approval Agency: KazInMetr
Approval Number: 12134MetrologyRussian -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-, FDU96-, FMU90-, FMU95-
Region/Country: Slovakia
Approval Agency: SMUB
Approval Number: 018/144/10Metrology -
Prosonic M, Prosonic S, Prosonic T
Product Code: FMU95-, FMU90-, FMU44-, FMU43-, FMU42-, FMU41-, FMU40-, FMU30-, FDU96-, FDU95-, FDU93-, FDU92-, FDU91-, FDU90-
Region/Country: Belarus
Approval Agency: BEL
Approval Number: 9773MetrologyRussian -
Prosonic S
Product Code: FDU90-, FDU91-, FDU91F-, FDU92-, FDU93-, FDU95-
Region/Country: Canada
Approval Agency: CSAOrdinary Location Product SafetyEnglish
Accessories / Spare parts
-
-
Order code
Unit is not repairable.
-