El Grupo Endress+Hauser

Sala de prensa

Eventos

Su carrera profesional en Endress+Hauser

Herramientas

Información de contacto

Radar measurement
Time-of-Flight
Micropilot FMR54

For level measurement in liquids where strong steam or ammonia can occur

  • Micropilot FMR54 aluminum housing with horn antenna and flange ©Endress+Hauser
  • Micropilot FMR54 aluminum housing with planar antenna ©Endress+Hauser
  • Micropilot FMR54 for high temperature with aluminum housing ©Endress+Hauser
  • Time-of-Flight measuring principle

  • Commissioning movie for Micropilot FMR5x free space radar and Levelflex FMP5x guided radar

  • Unique HistoROM data management concept for safe level measurement

  • Continuous adapting algorithms offering safe level measurement due to Multi-Echo Tracking

Micropilot FMR54 is prepared for the use in high temperature and high pressure applications and with the specially designed planar antenna it is particularly suited for stilling well applications. The FMR54 free space radar is used for continuous, non-contact level measurement of liquids, pastes and slurries. The measurement is not affected by changing media, temperature changes, gas blankets or vapors.

Ventajas

  • Hardware and software developed according to IEC 61508 up to SIL3 (in homogeneous redundancy)

  • HistoROM data management concept for fast and easy commissioning, maintenance and diagnostics

  • Highest reliability even in the presence of obstructions in the vessel due to new Multi-Echo Tracking evaluation

  • Reliable measurement even for changing product and process conditions

  • Heartbeat Technology for a cost-effective and safe plant operation during the entire life cycle

  • Seamless integration into control or asset management systems and intuitive, menu-guided operation concept (on-site or via the control system)

  • World's easiest proof test concept for SIL and WHG saves time and cost

Ámbito de aplicación

Horn antenna or planar antenna which is particularly suited for stilling well applications.

  • Process connection: Flange

  • Temperature: -196 to +400°C (-76 to +752°F)

  • Pressure: -1 to +160bar (-14.5 to +2,320psi)

  • Maximum measuring range: 20m (66ft)

  • Accuracy: ±6mm

  • C-band: 6GHz

  • International explosion protection certificates, overfill prevention WHG, SIL, 5-point linearity protocol

Características y especificaciones

Documentos / Manuales / Software

Accesorios / Piezas de repuesto

Predecesor / Sucesor

Predecesor: Micropilot M FMR230

Contacto

Endress+Hauser Instruments International AG
Marina Norte Avenue Plaza Real Offices 311, 312 & 314, Costa Del Este Panama City Panamá
Tel.: +507 275 58 00
Enviar correo electrónico

Noticias relacionadas

Este sitio Web utiliza cookies. Si Ud. continúa navegando por este sitio Web, consideramos que acepta el uso de cookies. Encuentre más información aquí cerrar

Seleccione su país / región